Implementation of a Low Cost For Internal Dosimetry Radiological Survey of Ionization Radiation Exposed Workers In Nuclear Medicine Services

DOI
https://doi.org/10.15415/jnp.2017.51014

AUTHORS

J Valle, A Angeles and T García

ABSTRACT

Because the nature of the routine activities carried on in nuclear medicine services, where several not sealed radioactive sources are used, the occupational personal exposed to ionization radiation (POE) is exposed to both, internal and external radioactive contamination and direct radiation also. The most important radioisotope from the point of view of radiological risk in such Nuclear Medicine Services (NMS) is the 131I. The Mexican official regulatory organization in radiological and nuclear safety: Comisión de Seguridad Nuclear y Salvaguardias (CNSNS) specify, as a requirement in the operation license of Nuclear Medicine Services the mandatory of internal and external dosimetry survey of POE. The external dosimetry survey is normally carried out but the internal dosimetry survey is not easy to do, because internal dosimetry systems are too expensive and in Mexico there are only three organizations (CFE-CLV, ININ, CNSNS) where there are these systems but they aren´t easily available for the Nuclear Medicine Services. Because that before fact, we propose a single, and low cost system (SLCS) to survey the internal dosimetry of POE. This system is based in a scintillation NaI(Tl) 2x2 detector and a common radiation monitor tipically used in the routine radiation and contamination measures, with a minimal infrastructure investment. This system is numerical calibrated with Montecarlo method, and compared with an well established commercial System being a good function corresponding. This system is easy to implementing in any nuclear medicine to complain the requirement of operation license in the internal dosimetry POE survey.

KEYWORDS

NaI(TI) detector, Energy Calibration, Efficiency Calibration, MCNP.

REFERENCES

  • Berger, M.J, (1963). Monte Carlo Calculation of Penetration and Difussion of fast charged particles.
  • Bogi B,(2015). International Dosimetry Exercise for Enhanced Ability
  • Bronson F.Z, (1996). Validation of the MCNP Monte Carlo code for Germanium detector gamma efficiency calibration. Tuccon.
  • Eberline, (1991). Smart Radiation Technical Manual model SMR-200
  • IAEA, (1999). Assessment of Ocupational Exposure Due to Intakes of Radionuclides. Report No: RS-G1.2.
  • ICRP, (1977). Limits For Intakes Of Radionuclides Wokers. Report No:30
  • Knoll, GF, (2000). Radiation Detection and Measurement
  • Laboratory LAN (2008). MCNP user´s manual. Los Alamos National Laboratory.
  • Reglamento General de Seguridad Radiológica, (1988), (pp. 1-60). México: D.F.
  • Diago, J,R, (2005). Simulation of Detector calibration using MCNP.
Call for Papers Publication Policy Instructions to the Authors Paper Submission Subscription Form Copyright Form Author Profile Format Sample paper Recommend to a Librarian

Refereed Research Journal

Member of CrossRef

Index Copernicus Value

ICV 2014: 43.38

Indexing









Call for Papers

Invites Papers for next issue of Journal of Nuclear Physics, Material Sciences, Radiation and Applications

Frequency

Journal of Nuclear Physics, Material Sciences, Radiation and Applications is published Bi - Annually

Number-1 August
Number-2 February